ABSTRACT

The initial cost of the power inverter system is significant higher compared to the conventional source of power. As a result, there is need for the performance evaluation of various power inverters in order to determine the cost efficiency of the power inverter as an alternative source of power. The aim of the present study is to investigate the performance index of 3.5KVA/48V inverters for domestic source of electric power supply. Four types of inverters (Mercury, Safer Power, Sinergy and Su-Kam) commonly available in the market were considered. And three performance indices (resistive load test, inductive load test and output waveform) were used to determine the cost effectiveness of one inverter over the other. Results showed that the Sinergy Power Inverter has the best performance. In terms of the battery discharge current, Sinergy is 35% (for the resistive) and 61% (for inductive test) more efficient compared to Mercury at an output load of 1 kW.

CHAPTER ONE

INTRODUCTION

1.1     Background to the Study

Electric power interruptions are quite common in every place, especially after a heavy down pour or a severe storm. To counter this power outage, a search has been to find a reliable and economical alternative source of electricity. Although this kind of project has been dealt with for quite a number of time but the fact still remains that an improvement needs to be done. This in essence makes the project topic “Investigation of the performance index of 3.5KVA/48V inverter” purposeful and resourceful.

        An inverter is a device or an electronic that converts or inverts a direct current into a conventional alternating current. A power inverter is a great tool used to run household / office appliances, where there is no electricity. The input voltage and frequency of the inverter may be fixed or it may vary depending on its application. Inverters finds several applications of which are the valuable speed, alternating current motors, uninterrupted power supply etc. They can be used as the front stage of dc to dc converter. Standby inverters are mostly used to provide emergency supply to the main frequency (50Hz). In the event of main failure, the inverter immediately operates with no loss of waveform. This unique ability makes it related to an automatic change over switch but it differs in a way in that it has a battery, which stores energy when the mains is on and gives out energy when the mains is off while the automatic change over switch operates on contactor (open and close).

         There are many types of inverter as described in chapter 2, but they all have the same principle of operations and it all depends on the component used, whether with a thyristor or a bipolar junction transistor for switching the current ON/OFF. The need for man to prevent his activities from being interrupted in order not to render it incomplete which may subsequently become an unfinished job (loss of files in the computer when there is a sudden power outage) has motivated engineers across the globe to design a device which will be more economical, durable and efficient.

It is pertinent to note that in a well organized company in a developing country like Nigeria, where a lot of transactions are made, if there is an epileptic power supply, the flow of transaction will greatly be hindered and there will be no open ground for the infant companies to spring up and wax great. Power should not be an obstruction between companies and their maximum profits, this in essence makes the use of a power inverter relevant and recommended to all and sundry. Hence, the need for the investigation of the performance index of various inverters comes to play. And this helps to determine which inverter is more efficient, portable, durable, and cost effective.

1.2     Statement of the Problem

The primary aim of engineers in the society is to solve the problems militating against technological growth, provide solutions to challenges facing humanities and bringing about efficient flow of ideals and innovators in the world of technology throughout the society and all nation of the earth. Inverter is that device which is being employed by the engineers to tackle and support the power supplies. This support comes to play when there is power outage. Immediately, the power inverter begins to act in place of the main power. Inverter are used in the conversion of direct current to a conventional alternating current, but the need for a reliable and more efficient, stable power supplies make the inverter indispensable especially in developing country like Nigeria where there is an epileptic power supply. Hence the need for investigation of the performance index of 3.5kVA/48V inverter in relation to other inverters becomes vital.

           Although, the electric power in an alternating current form is very difficult to store due to power loss which are associated with the alternating current and when converted, it can be in stored in the battery of which can be recharged.

1.3     Aim of the Study

The aim of the study is to evaluate the performance index of 3.5KVA/48V inverters for domestic electric power supply.

1.4     Objectives of the Study

                The objectives of the study are stated as follow.

To determine the output wave form of the inverter To determine the battery discharging current/voltage on load and the effect of load on the inverter The determine the  power efficiency (real-time output power ratings)

1.5     Methodology

`        The methods adopted to achieve the set objectives are as follows.

The Cathode ray oscilloscope was used to measure output wave form. The resistive and inductive load tests were applied to determine the battery discharging current/voltage on load and the effect of loads on the selected inverter Clamp meter, amp meter and volt meter were utilized.

1.6     Scope of the Study

In this study, the capacity of power inverters considered is 3.5KVA/48V with an output of 220-230V, frequency of 50Hz. And four different inverters vendors selected are Mercury, Safer power, Sinergy and Su-kam.  The choice of selection is based on the availability, portability, customer patronage and assesses to parts or repair.

1.7     Significance of the Study

          The study can enable:

the individual to have basic knowledge  about inverter; the energy consumer decide on the most economic inverter to install create more awareness on the use of inverter.

1.8     Arrangement of the Work

The study is divided into five chapters. Chapter one has been discussed. Chapter two gives a description of power inverters and battery, and what to look out for before buying inverter.

Chapter three discussed the experimental setup of the 3.5KVA/48V inverters for various inverters, and how it was analysed. The arrangement is based on the selected load specification of 1000VA.

In chapter four, the results of the performance of various inverter used as a case study, were presented and discussed.

Chapter five gives the conclusion and recommendation of the study.

  DOWNLOAD THE COMPLETE PROJECT

INVESTIGATION OF THE PERFORMANCE INDEX OF 3.5KVA/48V POWER INVERTER

Not The Topic You Are Looking For?



For Quick Help Chat with Us Now!

+234 813 292 6373

+233 55 397 8005


HOW TO GET THE COMPLETE PROJECT ON INVESTIGATION OF THE PERFORMANCE INDEX OF 3.5KVA/48V POWER INVERTER INSTANTLY

  • Click on the Download Button above.
  • Select any option to get the complete project immediately.
  • Chat with Our Instant Help Desk on +234 813 292 6373 for further assistance.
  • All projects on our website are well researched by professionals with high level of professionalism.

Here's what our amazing customers are saying

Abdulrahman Jibrin
Nti Abaji
Nice one work prompt delivery tanx
Very Good
Azeez Abiodun
Moshood Abiola polytechnic
I actually googled and saw about iproject master, copied the number and contacted them through WhatsApp to ask for the availability of the material and to my luck they have it. So there was a delay with the project due to the covid19 pandemic. I was really scared before making the payment cause I’ve been scammed twice, they attended so well to me and that made me trust the process and made the payment and provided them with proof, I got my material in less than 10minutes
Very Good
Adam Alhassan Yakubu
UDS
Excellent work and delivery , I promise to share my testimonies everyone in need of this kind of work. You're the best
Excellent
Joseph M. Yohanna
Thanks a lot, am really grateful and will surely tell my friends about your website.
Excellent
Merry From BSU
I am now a graduate because of iprojectmaster.com, God Bless you guys for me.
Excellent
Peace From Unilag
I cried not knowing how to go about my project but the day i searched online and saw iprojectmaster, i called and got my full project in less than 15minutes, i was shocked!
Excellent
Samuel From Ajayi Crowther University
You guys just made life easier for students. Thanks alot iprojectmaster.com
Excellent
JONNAH EHIS
Ajayi Crowther University, Oyo
I was scared at first when I saw your website but I decided to risk my last 3k and surprisingly I got my complete project in my email box instantly. This is so nice!!!
Excellent
Abraham Ogbanje
NATIONAL OPEN UNIVERSITY OF NIGERIA
At first I was afraid.. But I discovered they are legit. I will bring more patronize
Very Good
Ibrahim Muhammad Muhammad
Usmanu danfodiyo university, sokoto
It's a site that give researcher student's to gain access work,easier,affordable and understandable. I appreciate the iproject master teams for making my project work fast and available .I will surely,recommend this site to my friends.thanks a lot..!
Excellent

FREQUENTLY ASKED QUESTIONS

How do I get this complete project on INVESTIGATION OF THE PERFORMANCE INDEX OF 3.5KVA/48V POWER INVERTER?

Simply click on the Download button above and follow the procedure stated.

I have a fresh topic that is not on your website. How do I go about it?

How fast can I get this complete project on INVESTIGATION OF THE PERFORMANCE INDEX OF 3.5KVA/48V POWER INVERTER?

Within 15 minutes if you want this exact project topic without adjustment

Is it a complete research project or just materials?

It is a Complete Research Project i.e Chapters 1-5, Abstract, Table of Contents, Full References, Questionnaires / Secondary Data

What if I want to change the case study for INVESTIGATION OF THE PERFORMANCE INDEX OF 3.5KVA/48V POWER INVERTER, What do i do?

Chat with Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

How will I get my complete project?

Your Complete Project Material will be sent to your Email Address in Ms Word document format

Can I get my Complete Project through WhatsApp?

Yes! We can send your Complete Research Project to your WhatsApp Number

What if my Project Supervisor made some changes to a topic i picked from your website?

Call Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

Do you assist students with Assignment and Project Proposal?

Yes! Call Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

What if i do not have any project topic idea at all?

Smiles! We've Got You Covered. Chat with us on WhatsApp Now to Get Instant Help: +234 813 292 6373

How can i trust this site?

We are well aware of fraudulent activities that have been happening on the internet. It is regrettable, but hopefully declining. However, we wish to reinstate to our esteemed clients that we are genuine and duly registered with the Corporate Affairs Commission as "PRIMEDGE TECHNOLOGY". This site runs on Secure Sockets Layer (SSL), therefore all transactions on this site are HIGHLY secure and safe!